logo
Inicio ProductosEl conductor desnudo

Galvanized Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires

Certificación
China. Zhongdong Cable Co., Ltd. certificaciones
China. Zhongdong Cable Co., Ltd. certificaciones
Estoy en línea para chatear ahora

Galvanized Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires

Galvanized  Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires
Galvanized  Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires

Ampliación de imagen :  Galvanized Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires

Datos del producto:
Lugar de origen: Hebei, China
Nombre de la marca: Zhongdong
Certificación: CCC,IEC,VDE,TUV,ISO
Número de modelo: AAC
Pago y Envío Términos:
Cantidad de orden mínima: Negociable
Precio: Negociable
Detalles de empaquetado: Tambor de madera
Tiempo de entrega: 7-30 días basados en una cantidad diferente
Condiciones de pago: , L/C, T/T
Capacidad de la fuente: 500 km/semana

Galvanized Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires

descripción
Gama de aplicaciones: Transmisión aérea, tierra aérea Material: ACSR
Embalaje del tambor: Tambor de madera de acero Nombre del producto: Conductor ACSR Conejo
Tipo: El conductor desnudo Estándar: El número de unidades de producción será el siguiente:

 Galvanized  Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires


APPLICATION

Steel Wire Galvanized is suitable for overhead line stay wires, binding and jointing wires


CONSUTRUCTION
 

  • Core Material
  • Zinc Coating
Galvanized  Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires 0


STANDARD

  • For armouring galvanized steel wireBS EN 10244-2:2001&BS EN 10257-1:1998
  • BS EN 1442:1969
  • For ACSR galvanized steel wireASTM B 498/B 498M:1998(Reapproved 2002)ASTM A 443:1982BS EN 50189:2000(ST1AVST2B/ST3D/ST4A)IEC 60888:1987And so on.
  • ACSR galvanized steel wireASTM A 475:2003
  • ASTM A 363:2003(Reapproved 2009)ASTM B 500/B 500M:2009ASTM B 802/B 802M:2002
  • BS EN 215 PART 2:1970IEC 61089:1997AS 1222.1:1992CAN/CSA G12:1992(Reapproved 2003)And so on.


CHARACTERISTIC

 

  • ‌Corrosion Resistance‌
  • High Tensile Strength
  • Surface Properties‌
  • ‌Flexibility‌
  • ‌Electrical Conductivity


SPECIFICATION


Stranding & Wire Diameler

Overall
  Diameter


Sectional Area


Approximate
Weight


Breaking
Load


DC
Resistance

Alumimium

Steel


Aluminium


   Steel


Total

mm

mm

mm

mm²

mm²

kg/km

kN

ohm/km

A

6/1.98

1/1.98

5.43

18.4

3.07

21.5

74.4

9.02

1.7934

6/2.47

1/2.47

7.41

28.8

4.80

33.6

116.2

13.96

1.1478

6/3.13

1/3.13

9.38

46.0

7.67

53.7

185.9

22.02

0.7174

6/3.92

1/3.92

11.80

72.5

12.10

84.6

292.8

34.68

0.4555

18/2.85

1/2.85

14.30

115.0

6.39

121.0

266.4

41.24

0.2880

18/3.19

1/6.19

16.00

144.0

7.99

152.0

458.0

51.23

0.2304

26/2.65

7/2.06

16.80

144.0

2340

167.0

579.9

69.86

0.2310

18/3.61

1/3.61

18.00

184.0

10.20

294.0

586.2

65.58

0.1800

26/3.00

7/2.34

19.00

184.0

30.00

214.0

742.3

88.52

1.1805

18/4.04

1/4.04

20.20

230.0

12.80

243.0

732.8

81.97

0.1440

26/3.36

7/2.61

21.30

230.0

37.50

268.0

927.9

110.64

0.1444

22/4.08

7/2.27

23.10

288.0

28.30

316.0

1,013.5

117.09

0.1154

26/3.75

712.92

23.80

288.0

46.90

335.0

1,159.8

138.31

0.1155

45/3.20

7/2.14

25.60

363.0

25.10

388.0

1,196.5

136.28

0.0917

26/4.21

7/3.28

26.70

363.0

59.00

422.0

1,461.4

171.90

0.09117

45/3.61

7/2.41

28.90

460.0

31.80

492.0

1,519.4

172.10

0.0722

54/3.29

7/3.29

29.70

460.6

59.70

520.0

1,738.0

201.46

0.0723

45/3.83

7/2.55

30.60

518.0

35.80

554.0

1,709.3

193.61

0.0642

54/3.49

7/3.49

31.50

518.0

67.10

585.0

1,955.6

226.64

0.0643

45/4.04

7/2.69

32.30

575.0

39.80

615.0

1,899.3

215.12

0.0578

Stranding & Wire Diameler

Overall
  Diameter


Sectional Area


Approximate
Weight


Breaking
Load


DC
Resistance

Alumimium

Steel


Aluminium


   Steel


Total

mm

mm

mm

mm²

mm²

kg/km

kN

ohm/km

A

54/3.68

7/3.68

33.20

575.0

74.60

650.0

2,172.9

251.82

0.0578

45/4.27

7/2.85

34.20

645.0

44.60

690.0

2,127.2

240.93

0.0516

54/3.90

19/2.34

35.10

645.0

81.60

727.0

2,420.9

283.21

0.0516

72/3.58

7/2.39

35.80

725.0

31.30

756.0

2,248.0

249.62

0.0459

54/4.13

19/2.48

47.20

725.0

91.80

817.0

2,723.5

318.61

0.0459

72/3.80

7/2.53

38.00

817.0

35.30

852.0

2,533.4

281.32

0.0407

54/4.39

19/2.63

39.50

817.0

104.00

921.0

3,069.4

359.06

0.0407

72/4.04

7/2.69

40.40

921.0

39.80

961.0

2,854.6

316.98

0.0361

84/3.74

7/3.74

41.10

921.0

76.70

998.0

3,145.1

356.03

0.0361

72/4.28

7/2.85

42.80

1,036.0

44.80

1,081.0

3,211.4

356.60

0.0321

84/3.96

7/3.96

43.60

1,036.0

86.30

1,122.0

3,538.3

400.53

0.0322

84/4.28

19/2.51

45.90

1,151.0

93.70

1,245.0

3,916.8

446.37

0.0289

84/4.42

19/2.65

48.60

1,289.0

105.00

1,394.0

4,386.8

449.93

0.0258


ABOUT US


Galvanized  Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires 1

    

OUR WAREHOUSE

Galvanized  Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires 2


WHY US


Galvanized  Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires 3



PARTNER


Galvanized  Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires 4Galvanized  Steel Wire GSW Bare Conductor for Overhead Line Stay wires Binding and Jointing Wires 5


FAQ

Q.What is galvanized steel wire used for in cables?
A. Galvanized steel wire provides tensile strength and corrosion resistance, making it ideal for overhead power lines, suspension bridges, and animal fencing.

Q.How does galvanization protect steel wire?
A.The zinc coating acts as a sacrificial layer, preventing rust even when exposed to moisture or harsh environments.

Q‌.What are the common diameters of galvanized steel wire cables?
A.Standard ranges from 1.2mm to 6mm, with thicker wires used for heavy-duty applications like construction nets.

Q‌. Is galvanized steel wire suitable for marine environments?
A. Yes, but for saltwater exposure, higher zinc coating (e.g., 275g/m²) is recommended to prevent premature corrosion.

Q.Can galvanized steel wire be welded?
A. Yes, but the zinc coating must be removed first to avoid toxic fumes and weak joints.

Q‌.What’s the difference between electro-galvanized and hot-dipped galvanized wire?
A.Hot-dipped offers thicker zinc layers (better durability), while electro-galvanized provides a smoother finish for finer cables.

Q‌.Does galvanized wire conduct electricity?
A. Yes, but it’s primarily used as structural support in composite cables, not as the primary conductor.

Q‌.How long does galvanized steel wire last outdoors?
A.Typically 20-50 years, depending on coating thickness and environmental conditions (e.g., industrial pollution reduces lifespan).

Q‌. Is galvanized wire recyclable?
A. Absolutely—both steel and zinc are recyclable materials, often reused in new metal products.

Contacto
Zhongdong Cable Co., Ltd.

Persona de Contacto: Mr. Bai

Teléfono: +8619829885532

Envíe su pregunta directamente a nosotros (0 / 3000)